Fig 1

NORMAL SERVICE POSITION
15mm PIPEWORK
Fig 1 above shows the water softener in the normal Service
position i.e.
Inlet Valve: This valve is Open when the blue handle is parallel
to the sides of the isolating valve that has the hose connected to it.
Outlet Valve: This valve is Open when the blue handle is parallel
to the sides of the isolating valve that has the hose connected to it.
Bypass Valve: This valve is Closed when either a Black handle
or Screwdriver slot is at 90degrees to the isolating valve connected in the
copper pipe work.
22mm PIPEWORK
The layouts are exactly the same as above but with 22mm applications
the Inlet, Outlet and Bypass valve are chrome plated valves with
screwdriver slots.
BYPASSING YOUR WATER SOFTENER
15mm PIPEWORK
Inlet Valve: Turn blue handle 90 degrees so
it closes the flow of water through this valve.
Outlet Valve: Turn blue handle 90 degrees so
it closes the flow of water through this valve also.
Bypass Valve: Turn Black handle or Screwdriver
slot 90 degrees so that it is now parallel to the sides of the
isolating valve, this will then open this valve and allow water
through to your system.
22mm PIPEWORK
Simply turn the Screwdriver slots in the Inlet, Outlet and Bypass
valves 90 degrees. This effectively closes the flow of water through
the Inlet and Outlet Valves and opens the Bypass Valve for water
through to your system.
Fig 2

BYPASSING YOUR WATER SOFTENER
FOR TEE VERSION BYPASS INSTALLATIONS
NORMAL SERVICE POSITION – all handles face the same way.
15mm PIPEWORK
Fig 2 above shows the water softener in the normal Service position
i.e.
Inlet Valve: This valve is Open when the blue handle is 90 degrees to the sides of the isolating valve that has the hose connected to it i.e. it ‘points’ to the hose connection.
Outlet Valve: This valve is Open when the blue handle is 90 degrees to the sides of the isolating valve that has the hose connected to it i.e. it ‘points’ to the hose connection.
Bypass Valve: This valve is Closed when either a Black handle or Screwdriver slot is at 90degrees to the isolating valve connected in the copper pipe work.
BYPASSING YOUR WATER SOFTENER – all handles have effectively been turned 90 degrees.
15mm PIPEWORK
Inlet Valve: Turn blue handle 90 degrees so it closes the flow of water through this valve so handle is now parallel to plastic nut on the hose connection.
Outlet Valve: Turn blue handle 90 degrees so it closes the flow of water through this valve so handle is now parallel to plastic nut on the hose connection.
Bypass Valve: Turn Black handle or Screwdriver slot 90 degrees so that it is now parallel to the sides of the isolating valve, this will then open this valve and allow water through to your system.